Sensing Specifications
- Temperature sensor with signal conditioning and linearization manufactured by Analog Devices.
- Physical Range Sensed: approximately -20C to 50C (-4F to 122F).
Electrical Specifications
- Voltage Source: 0-5 Volts
- Minimum Current Source: 1.5mA
- Voltage Returned by Sensor: Industry Standard 0.25 Volts to 4.75 Volts, fully conditioned and buffered.
- Connector Layout (Pin 1 is indicated by an arrow on the top of the connector)
- Pin 1: Ground (from interface )
- Pin 2: Sensor Output
- Pin 3: 5 Volts (from interface)
|
Cable Specifications
- Electrotap P/N: CAB-MX2LF3-3
- Standard 3 foot (approximately 1 meter) premium quality Canare L-4E5C star-quad cable with braided shielding.
- Sensor-end connector is our standard, female locking Molex connector. Interface-end connector is top-of-the-line Neutrik XLR connector.
- Molex connector layout:
- Pin 1: Ground
- Pin 2: Sensor Output
- Pin 3: 5 Volts
- XLR connector layout:
- Pin 1: Ground
- Pin 2: 5 Volts
- Pin 3: Sensor Output
|
Application Examples
- Ambient / environmental temperature (note however that the sensor is not weather proof)
- Body temperature: touching or breathing on the sensor for example (this yields the best results when the temperature sensor is used in conjunction with our T200 Scaler).
Application Notes
- The temperature sensing component used in this device is actually capable of a larger temperature range. This sensor has been designed to focus on a smaller range to improve resolution in that range, but the sensor may be customized if the larger range is required.
|